WOS advanced search query (RED – proceedings): PŘÍMÝ LINK
UT=000330143000071 OR UT=000306027000016 OR UT=000291134200016 OR UT=000291335900014 OR UT=000270625900072 OR UT=000252951400008 OR UT=000268844200002 OR UT=000275655200339
BibTeX entries:
@ARTICLE{Peksa:14:Implementation,
author = {Peksa, L. AND Gronych, T. AND Jerab, M. AND Vicar, M. AND Stanek, F. AND Krajicek, Z. AND Prazak, D.},
title = {Implementation of multi-opening orifices in the primary metrology of vacuums and small gas throughputs},
journal = {Vacuum},
fulljournal = {VACUUM},
volume = {101},
number = {1},
pages = {377--381},
year = {2014},
issn = {0042-207X},
doi = {10.1016/j.vacuum.2013.10.014},
KFPPid = {1355},
}
@ARTICLE{Gronych:12:Experimental,
author = {Gronych, T. AND Jerab, M. AND Peksa, L. AND Wild, J. AND Stanek, F. AND Vicar, M.},
title = {Experimental study of gas flow through a multi-opening orifice},
journal = {Vacuum},
fulljournal = {VACUUM},
volume = {86},
number = {11},
pages = {1759--1763},
year = {2012},
issn = {0042-207X},
doi = {10.1016/j.vacuum.2012.02.008},
KFPPid = {1267},
}
@ARTICLE{Peksa:11:Method,
author = {Peksa, L. AND Gronych, T. AND Vicar, M. AND Jerab, M. AND Repa, P. AND Tesar, J. AND Prazak, D. AND Krajicek, Z. AND Stanek, F.},
title = {Method of measuring the change in volume of a diaphragm bellows used in a volume displacer of a constant-pressure gas flowmeter (with a practical guide)},
journal = {Measurement},
fulljournal = {Measurement},
volume = {44},
number = {6},
pages = {1143--1152},
year = {2011},
issn = {0263-2241},
doi = {10.1016/j.measurement.2011.03.008},
KFPPid = {1095},
}
@ARTICLE{Peksa:11:Dynamic,
author = {Peksa, L. AND Gronych, T. AND Jerab, M. AND Repa, P. AND Vicar, M. AND Krajicek, Z. AND Prazak, D. AND Stanek, F. AND Tesar, J.},
title = {Dynamic extension – A new principle for a vacuum primary standard for UHV-range (10−6–10−10 Pa) calibration of hot cathode ionisation gauges},
journal = {Vacuum},
fulljournal = {VACUUM},
volume = {85},
number = {11},
pages = {1047--1051},
year = {2011},
issn = {0042-207X},
doi = {10.1016/j.vacuum.2011.03.019},
KFPPid = {1096},
}
@ARTICLE{Gronych:09:Changes,
author = {Gronych, T. AND Peksa, L. AND Prazak, D. AND Vicar, M. AND Repa, P. AND Krajicek, Z. AND Stanek, F. AND Tesar, J.},
title = {Changes in the NPL orifice conductance on a transition from molecular gas flow to transitional flow},
journal = {Vacuum},
fulljournal = {VACUUM},
volume = {84},
number = {1},
pages = {280--282},
year = {2009},
issn = {0042-207X},
doi = {10.1016/j.vacuum.2009.04.009},
KFPPid = {936},
}
@ARTICLE{Gronych:08:The,
author = {Gronych, T. AND Peksa, L. AND Repa, P. AND Wild, J. AND Tesar, J. AND Prazak, D. AND Krajicek, Z. AND Vicar, M.},
title = {The use of diaphragm bellows to construct a constant pressure gas flowmeter for the flow rate range 10^(-7) Pa m^3 s^(-1) to 10^(-1) Pa m^3 s^(-1)},
journal = {Metrologia},
fulljournal = {METROLOGIA},
volume = {45},
number = {1},
pages = {46--52},
year = {2008},
issn = {0026-1394},
doi = {10.1088/0026-1394/45/1/007},
KFPPid = {815},
}
Bibitems:
\bibitem[{Peksa et~al.(2014)}]{Peksa:14:Implementation}
Peksa, L., Gronych, T., Jerab, M., Vicar, M., Stanek, F., Krajicek, Z., Prazak, D., Implementation of multi-opening orifices in the primary metrology of vacuums and small gas throughputs. {\it Vacuum.} {\bf 101}(1): 377--381, 2014.
\bibitem[{Gronych et~al.(2012)}]{Gronych:12:Experimental}
Gronych, T., Jerab, M., Peksa, L., Wild, J., Stanek, F., Vicar, M., Experimental study of gas flow through a multi-opening orifice. {\it Vacuum.} {\bf 86}(11): 1759--1763, 2012.
\bibitem[{Peksa et~al.(2011)}]{Peksa:11:Method}
Peksa, L., Gronych, T., Vicar, M., Jerab, M., Repa, P., Tesar, J., Prazak, D., Krajicek, Z., Stanek, F., Method of measuring the change in volume of a diaphragm bellows used in a volume displacer of a constant-pressure gas flowmeter (with a practical guide). {\it Measurement.} {\bf 44}(6): 1143--1152, 2011.
\bibitem[{Peksa et~al.(2011)}]{Peksa:11:Dynamic}
Peksa, L., Gronych, T., Jerab, M., Repa, P., Vicar, M., Krajicek, Z., Prazak, D., Stanek, F., Tesar, J., Dynamic extension – A new principle for a vacuum primary standard for UHV-range (10−6–10−10 Pa) calibration of hot cathode ionisation gauges. {\it Vacuum.} {\bf 85}(11): 1047--1051, 2011.
\bibitem[{Gronych et~al.(2009)}]{Gronych:09:Changes}
Gronych, T., Peksa, L., Prazak, D., Vicar, M., Repa, P., Krajicek, Z., Stanek, F., Tesar, J., Changes in the NPL orifice conductance on a transition from molecular gas flow to transitional flow. {\it Vacuum.} {\bf 84}(1): 280--282, 2009.
\bibitem[{Gronych et~al.(2008)}]{Gronych:08:The}
Gronych, T., Peksa, L., Repa, P., Wild, J., Tesar, J., Prazak, D., Krajicek, Z., Vicar, M., The use of diaphragm bellows to construct a constant pressure gas flowmeter for the flow rate range 10^(-7) Pa m^3 s^(-1) to 10^(-1) Pa m^3 s^(-1). {\it Metrologia.} {\bf 45}(1): 46--52, 2008.